  Project Summary Collage - 1  
 
               
Installation of Air Sparging/Soil Vapor Extraction and Monitoring Wells at Former Steel Manufacturing Facility
                    Southern Ohio
                    As part of the remediation activities at the site, GEO installed:
                    98 Test Borings using screen 3-1/4 inch HSA for collection of in situ groundwater and soil samples.
                    120 Air Sparging (AS) points to a depth of 60 feet.
                    76 Dual Air Sparging/Soil Vapor Extraction (AS/SVE) Wells to a depth of 60 feet.
                    230 concrete cores (8 and 14 inches diameter) inside a large manufacturing building in concrete up to 24 inches thick.
                    Other site activities included management of investigative derived wastes (soil and water), grouting and decontamination of drilling equipment.